Fan Coil Unit with Water Collection Tray

FOB Price: Get Latest Price
Min. Order: 10 Pieces
Production Capacity: 200000
Transport Package: Carton or Wooden
Payment Terms: L/C, T/T, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: FCU
  • Blade Material: Galvanizing Al-Zn
  • Electric Current Type: AC/Ec
  • Certification: RoHS, ISO, CE, SGS, CCC
  • Coil: Hydrophilic Aluminum Fin
  • Thermostat & Valve: Available for Option
  • Trademark: U&C
  • HS Code: 84159090
  • Material: Galvanizing Al-Zn
  • Type: Centrifugal Fan
  • Mounting: Duct Fan
  • Pipe: 2-Pipe Standard, 4-Pipe Optional
  • Electrical Heater: Available for Option
  • Filter: Nylon Filter
  • Origin: China
Product Description
Ceiling Concealed Fan Coil Unit (Ducted FCU)


Description:

Designed to be installed within false ceilings where minimum mounting space is available.

Concealed Ducted Fan Coils have been specially designed to be installed within false ceilings where minimum mounting space is available. It offers external static pressures suitable for the ducting of treated air to suit the majority of installation requirements.

We offer a complete product range, with multiple row coil designs, accessories for the majority of installation requirements, and constructional features to maximize the product flexibility, such as auxiliary heating coils and auxiliary electrical heaters suitable for on-site or in-stock installation.

Minimizes Costs- Maximizes Flexibility- Optimizes Distribution
√  3-speed centrifugal fan statically and dynamically balanced (for AC version)
√  EC Motor with modulating 0-5 V DC Input(for EC version)
√  Auxiliary Electric Heater Element for installation On-site or In-stock
√  Interchangeable left/right side coil connections
√  Auxiliary 1 row heating coil for installation On-site or in-stock
√  12,30 and 60 Pa External Static Pressure(ESP) models available (for AC version)
√  Variable External Static Pressures(ESP)up to 60 Pa(for EC version)

AC model + EC model

2 pipe from 
Cooling:  1.7 kw ~ 9.9 kw
Heating: 2.04 kw ~11.7kw

4 pip from
(with heating coil)
Cooling: 1.7 kw ~ 9.9 kw
Heating:1.9 kw ~ 10.2 kw


Controller


Fan Coil Unit with Water Collection Tray


FCU Breakdown:

Fan Coil Unit with Water Collection Tray






FCU Version:

Fan Coil Unit with Water Collection Tray





MULTIPLE FUNCTION:
Fan Coil Unit with Water Collection Tray


Production View:

Fan Coil Unit with Water Collection Tray


FCU Technical Data:
  FC-WA(3R)-[Size]-V~2003004005006008001000120014001600
Unit ConfigurationConfiguration2-pipe
Number Of Fan BlowersSingleTwinThreeFourThreeFour
Power Supply(V/Ph/Hz)230 / 1 / 50
220 / 1 / 60
Operation Control~S: Complete function onboard PCB with integrated group control functionality, incl. 1 pc return air sensor and 2 pcs temperature sensors.
~T: Terminal strip only.
Performance DataAirAir FlowH3m3/hr451 566 758 934 1179 1527 1754 1991 2586 2933 
M2358 457 615 840 958 1220 1605 1871 2389 2666 
L1278 293 433 571 779 896 1144 1573 2068 2482 
Available pressureH3Pa75757575757575757575
M275757575757575757575
L175757575757575757575
CoolingCooling CapacityH3Kw2.433.083.94.85.998.018.729.8712.814.6
M22.022.593.34.425.096.78.149.41213.5
L11.651.82.53.244.325.236.238.210.712.8
Sensible Cooling CapacityH31.742.22.823.464.315.736.357.169.2410.5
M21.441.842.383.183.644.775.916.818.669.71
L11.171.271.782.313.083.74.485.927.719.16
HeatingHeating CapacityH3Kw3.00 3.78 4.87 5.99 7.43 9.85 11.00 12.52 16.15 18.25 
M22.50 3.18 4.12 5.51 6.32 8.24 10.27 11.92 15.14 16.66 
L12.042.213.124.045.366.437.8610.413.516
Max. Electric Heater Capacity@220V1133333333
SoundSound Pressure Level ( Outlet )dB(A)40/38/3744/43/4043/41/3745/43/3949/47/4444/43/3947/46/4452/48/4452/48/4454/52/50
Sound Pressure Level ( Inlet + Radiated )43/41/4047/46/4346/44/4048/46/4252/50/4747/46/4250/49/4755/51/4755/51/4757/55/53
Sound Power Level ( Outlet )49/47/4653/52/4952/50/4655/53/4858/56/5153/52/4857/56/5361/57/5461/57/5363/61/60
Sound Power Level( Inlet + Radiated ) 52/50/4956/55/5255/53/4958/56/5161/59/5456/55/5160/59/5664/60/5764/60/5666/64/63
ElectricalFan Motor PowerH3W82 105 139 154 206 261 288 359 430 511 
M275 96 128 146 188 238 276 342 365 460 
L168 88 111 129 173 216 249 325 345 412 
Fan Motor Running Current @ HA0.36 0.46 0.61 0.67 0.93 1.14 1.22 1.61 1.95 2.33 
Fan Motor Starting Current @ HA1.08 1.14 1.35 1.95 2.10 2.70 3.52 4.81 5.65 6.75 
HydraulicCooling Water Flow Rate3L/h417528669827102913751498169421972501
234744556775887311501397161320642321
12833104285577418981069140818422194
Cooling Pressure Drop3KPa18.330.81726.742.842.717.322.742.257.2
213.322.912.823.132.131.315.420.837.950.2
19.3812.37.913.624.220.49.6816.531.145.5
Heating Water Flow RateL/hSame as "Cooling Water Flow Rate"
Heating Pressure Drop3KPa14.7524.8213.721.63524.81418.634.747.4
210.7218.4510.318.726.325.512.51731.241.6
17.569.916.361119.816.67.8513.525.637.7
water contentL0.72 0.87 1.02 1.17 1.32 1.92 2.07 2.22 2.59 2.84 
Construction and Packing DataWaterTypeSocket(Threaded Female)
ConnectionsIn mm [in]3/4"
 Out
Condensate Drainage Connection
DimensionsLmm755 855 955 1155 1255 1655 1755 1855 1755 1955 
W550 620 
H250 300 
Net WeightKg17 23 24 28 31 36 43 45 51 60 

a. Cooling mode:                                                                                     b. Heating mode:            
                                
- Return air temperature: 27C DB/ 19C WB.                                                - Return air temperature: 20C.            
- Inlet/ outlet water temperature: 7C/ 12C.                                                   - Inlet water temperature: 50C.            
                                                                                                               - Water flow-rate: same as cooling mode    