Vertical Exposed Chilled Water Fan Coil Unit Floor Standing

Product Details
Customization: Available
Material: Galvanizing Al-Zn
Blade Material: Galvanizing Al-Zn
Manufacturer/Factory, Trading Company, Other
Gold Member Since 2016

Suppliers with verified business licenses

Year of Establishment
2019-10-29
Management System Certification
ISO 9001, ISO 14000
  • Vertical Exposed Chilled Water Fan Coil Unit Floor Standing
  • Vertical Exposed Chilled Water Fan Coil Unit Floor Standing
  • Vertical Exposed Chilled Water Fan Coil Unit Floor Standing
  • Vertical Exposed Chilled Water Fan Coil Unit Floor Standing
  • Vertical Exposed Chilled Water Fan Coil Unit Floor Standing
  • Vertical Exposed Chilled Water Fan Coil Unit Floor Standing
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Company Profile
  • Project Reference
  • About Packing & Shipping:
Overview

Basic Info.

Model NO.
FP series
Type
Centrifugal Fan
Electric Current Type
AC/Ec
Mounting
Floor Standing / Ceiling
Certification
RoHS, ISO, CE, CCC
Pipe
2-Pipe Standard, 4-Pipe Optional
Function
Air Conditioner Parts, Fan Coil Unit
Air Volume
340~2380 CMH
Installation
Horizontally or Vertically
Coil
Hydrophilic Aluminum Fin
Product Name
Universal Type Fan Coil Unit
Product Description
Central HVAC System
Key Words
Air Conditioning Terminal Machine
Transport Package
Carton
Specification
up to 2380 CMH
Trademark
U&C
Origin
China
HS Code
84159090
Production Capacity
200000

Product Description

 

Product Description


Hydronic Universal Fan Coil Unit ( Room use)
The floor-standing universal fan coil is a type of heating, ventilation, and air conditioning (HVAC) system designed to provide both cooling and heating in commercial and residential spaces. It consists of a fan and a coil, which work together to regulate air temperature. The fan circulates air over the coil, which either cools or heats the air before distributing it throughout the room.
Vertical Exposed Chilled Water Fan Coil Unit Floor Standing
 

We have front air return and bottom return for optionVertical Exposed Chilled Water Fan Coil Unit Floor Standing

Universal design, the FCU can be installed by both horizontally and vertically.

Vertical Exposed Chilled Water Fan Coil Unit Floor Standing

We have six style FCU can be selected.
Vertical Exposed Chilled Water Fan Coil Unit Floor Standing
 Conceal Style Air inlet direction can be changed.
Vertical Exposed Chilled Water Fan Coil Unit Floor Standing


Easy maintenance 
Vertical Exposed Chilled Water Fan Coil Unit Floor Standing
 
ControllersVertical Exposed Chilled Water Fan Coil Unit Floor Standing
 

Product Parameters

 
Model FP-34 FP-51T FP-68 FP-85 FP-102 FP-136 FP-170 FP-204 FP-238
Power supply 220V,50Hz,1Ph
Air volume H m3/h 340 510 680 850 1020 1360 1700 2040 2380
M 260 390 510 640 770 1020 1280 1530 1790
L 170 260 340 430 510 680 850 1020 1190
Cooling capacity TH H W 1800 2700 3600 4500 5400 7200 9000 10800 12600
BTU/h 6142 9212 12283 15354 18425 24566 30708 36850 42991
SH W 1368 2052 2736 3420 4103 5471 6839 8207 9575
BTU/h 4668 7001 9335 11669 13999 18667 23335 28002 32670
TH M W 1494 2242 2989 3736 4483 5978 7472 8967 10461
SH W 1181 1771 2362 2952 3541 4722 5903 7084 8265
TH L W 1162 1744 2325 2906 3487 4649 5812 6974 8136
SH W 953 1430 1907 2383 2860 3813 4765 5718 6672
Heating capacity H W 2700 4050 5400 6750 8100 10800 13500 16200 18900
M W 2131 3197 4262 5328 6393 8524 10655 12786 14917
L W 1675 2511 3349 4186 5024 6697 8372 10046 11721
Noise H 0Pa dB(A) 37 39 41 43 45 46 48 50 51
Power input H 0Pa W 37 52 62 76 96 134 152 189 228
Waterflow volume   m3/h 0.31 0.46 0.62 0.77 0.93 1.23 1.54 1.85 2.16
Water pressure dropping kPa 7 15 18 23 28 30 22 30 36
Dimension of water(in & out)connection pipe in ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4"
out ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4"
coil type high efficient copper pipe to wear Hydrophilic aluminum coil
Maximum working pressure Mpa 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6
Condensation pipe size(diameter) mm ∅21
 

Testing condition:

2 pipe system:
Cooling: air entering temperature DB/WB(27/19.5C), 7C entering chilled water temperature and 5C water temperature rise.Heating:air entering temperature DB20, the water inlet temperature is 60C, whichwater flow is the same as the cooling data.The noise level be test front of the test unit with 1 meter on the noise room.

4 pipe system:
Cooling: air entering temperature DB/WB(27/19.5C), 7C entering chilled water temperature and 5Cwater temperature rise.Heating: air entering temperature DB20 C,the inlet/outlet water temperature:60C/50C The noise level be test front of the test unit with 1 meter on the noise room.


 

Detailed Photos


Vertical Exposed Chilled Water Fan Coil Unit Floor Standing
Vertical Exposed Chilled Water Fan Coil Unit Floor StandingVertical Exposed Chilled Water Fan Coil Unit Floor Standing

Company Profile

At Central Air Conditioning Solutions, Umbrellaclimate specialize in delivering top-tier climate control systems designed to enhance the comfort, efficiency, and sustainability of homes, businesses, and industrial spaces. With over 40 years of experience in the HVAC (Heating, Ventilation, and Air Conditioning) industry, we are a trusted partner for high-quality central air conditioning systems.

Our Mission

Our mission is simple: to provide reliable, energy-efficient, and cost-effective cooling and heating solutions that ensure optimal comfort for our customers. We aim to lead the industry in technological innovation and customer satisfaction, making comfort affordable and accessible to everyone.

Our Services

We offer a comprehensive range of services that include:

  • Custom Central Air Conditioning Installation: Tailored to fit the unique needs of residential, commercial, and industrial properties.
  • Maintenance & Repair: Regular servicing to ensure the longevity and peak performance of your air conditioning system.
  • Energy-Efficient Upgrades: Installation of the latest eco-friendly HVAC technologies to reduce energy consumption and costs.
  • 24/7 Customer Support: Our dedicated team is available around the clock to address any issues or queries.

Why Choose Us?

  • Expert Technicians: Our team of certified HVAC technicians brings decades of expertise to every project, ensuring precision and efficiency.
  • Quality Products: We partner with leading manufacturers to offer the most advanced and reliable air conditioning units.
  • Energy Efficiency: Our solutions are designed to help clients minimize energy usage while maximizing comfort, reducing both their carbon footprint and utility bills.
  • Customer Satisfaction: We prioritize customer satisfaction and pride ourselves on delivering tailored solutions that meet each client's specific needs.

Whether you need a new installation, system upgrade, or routine maintenance, Central Air Conditioning Solutions is your go-to expert for high-performance climate control systems. We are committed to keeping you cool and comfortable year-round.

Project Reference


Vertical Exposed Chilled Water Fan Coil Unit Floor Standing

About Packing & Shipping:

Vertical Exposed Chilled Water Fan Coil Unit Floor Standing
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier