Shanghai, China
Business Type:
Manufacturer/Factory, Trading Company, Other
Plant Area:
<100 square meters
Management System Certification:
ISO 9001, ISO 14000
Main Markets:
South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, ...
Average Lead Time:
Peak season lead time: 6-12 months
OEM/ODM Service

Heat Recovery Ventilator, Total Heat Exchanger, Fresh Air Unit manufacturer / supplier in China, offering Ceiling Type Heat Recovery Ventilator, Umbrellaclimate Clean Room Air Handling Unit, Air Purified Heat Recovery Ventilator and so on.

Gold Member Since 2016

Ceiling Type Heat Recovery Ventilator

Get Latest Price
Purchase Qty. / Reference FOB Price
1-99 Pieces US $305.93
100+ Pieces US $258.9
Port: Shanghai, China
Production Capacity: 50000
Payment Terms: T/T, Western Union
Usage: Air Purified
Flow Direction: Centrifugal
Pressure: Medium Pressure
Certification: CE
Motor: AC Standard, DC Optional
Air Volume: 100~5000 M3/H or Above

You Might Also Like

Loading...

Basic Info

Model NO.: UHE
Efficiency: 75%
Payment: by T/T
CO2 Controller: Optional
Trademark: U&C
Transport Package: Carton or Wooden
Specification: 150-5000 CMH
Origin: China
HS Code: 84145930

Product Description

Energy Recovery Air To Air Total Heat Exchanger:

(HRV/ERV) GENERAL CHARACTERISTICS:
1.Air volume(m3/h): 100/150/200/250/350/400/500/600/800/1000/1200 (could be higher)
2.High-efficiency filter
3.High-efficiency heat recovery core( Cross counter flow)
4.Unit Function: Air purification, energy recovery
5.Application: Meeting room, test room,office building,computor room,restaurant , shop , fitness and entertainment place etc.


OPTIONS

The following options can be provided:

1.Bypass function ,defrosting and inner thermal insulation 
2. DC Motor 
3. CO2 Sensor Controller 


Why  Choose us?

Compared with other supplier, we have advantages as following:
1.CE certified
2. Famous Brand DC motor: 50% energy saving & running quietly
3.Filter service life is for 2 years in Europe
4.Motor service life is for 10 years 
5.Heat recovery efficiency can reach  to 70-80%
6.Optional CO2 controller:  The test range can up to 5000ppm
7.Optional purifying box can be for PM 2.5
8.Optinoal bypass function is a good choice for the cold climate
9. Strictly production line flow be carry out
10.Delivery time: 7 working days after payment be received
11.Maintenance: 18 months against the B/L date.

Product Introduction:
1. Super light ultra-thin design, machine on condole top, do not take up among indoor space, and do not affect indoor decoration effect. The machine can also level invert direction installation, more flexibility. Unique structure design will duct censored technology applied to equipment in, guarantee the perfect mute effect. 
 
2. Besides having general change of fresh air, air purification, energy recycling and basic functions, but also equipped with different control system, which can achieve a variety of specific function of equipment. 
 
3. Brushless DC motor using Panasonic, less noise, super energy-saving, comprehensive energy saving more than 50%. 
 
4. Liquid crystal display control switch, but according to need to achieve timing open/close and airflow control, indoor temperature display, optional with temperature, concentration of carbon dioxide display and control function, achieve healthy controls. 
 
5. It is good choice for green buildings, environmentaly protection.



Clean Comfort Environment and Energy Saving: 
Ceiling Type Heat Recovery Ventilator
                                                                                   



Maintenance:
Ceiling Type Heat Recovery Ventilator

FAQ
1.Order type
 We accept small and mixed order, MOQ 1pc each model.
2.OEM & ODM
OEM & ODM, Customization service provided. 
We can customize ANY LOGO on the unit  according to your request. MOQ 1*20 Container.
3.Payment:
By T/T

4.Delivery time: 
 Standard is 7 working days after payment be received.
5.Maintenance: 
18 months against the B/L date.
 

We're sure your any inquiry will get prompt reply!
 
                                                                                                                                  Model Selection Guide
                           Room type                                                    Non-Smoking       Slight SmokingHeavy Smoking    
 Ordinary ward    Gym Theater&Mall    Office Computer 
 Room
 Dining room   VIP Room  Meeting Room
Personal fresh air consumption
(m3/h)(Q)
     17~42 8~208.5~2125~6240~10020~5030~7550~125
Air changes per hour(P)1.06~2.650.50~1.251.06~2.661.56~3.902.50~6.251.25~3.131.88~4.69 3.13~7.81          

Remark:

1.Choose the proper installation types based on the building structure;                                                                                                                     
2.Determine the fresh airflow required according to the use, size and number of persons;   
3.Select the right specifications and quantity according to the determined fresh airflow.

 

 

Send your message to this supplier

*From:
*To:
avatar Ms. Joyce
*Message:

Enter between 20 to 4,000 characters.